Applications
ACAR cables are used for overhead transmission and distribution lines.

Construction
Concentric-stranded cable formed by a core of 6201-T81 aluminum alloy wires surrounded by 1350 H-19 aluminum wires concentrically stranded over the alloy core.  Some designs have 1350 aluminum wires and 6201 alloy wires intercalated in the same layer.

Features
Very good ratio Tensile Strength to Weight.  Highly resistant to corrosion.

Standards
  • ASTM B-524

    Notes
    Current Carrying Capacity is based on 77oF (25oC) ambient temperature,
    167oF (75oC) conductor temperature, 2 ft/sec (0.6 m/s) wind velocity,
    0.5 Cable emissivity, sun 96 watts/sq.ft (1000 watts/mo), at sea level.


  • Search Items


    Request InformationCompare Items   Results per Page : 
      Results 1 - 37 of 37 1 

    Item #

    Size
    AWG
    or
    KCMIL

    SIZE mm2

    Total Number of Wires

    Number of 1350 Wires

    Number of 6201 Wires

    Wire Diameter (mils)

    Wire Diameter (mm)

    Overall
    Diameter
    (inches)

    Overall Diameter (mm)

    Nominal Mass lb/MFT

    Nominal Mass kg/km

    Rated Strength (kips)

    Rated Strength (kgf)

    Resistance At 20°F per 1000 ft. (Ω)

    Resistance At 20°F Per KM (Ω)

    Current
    Carrying
    Capacity
    Sun, No Wind

    Current
    Carrying
    Capacity
    Sun and Wind

    Current
    Carrying
    Capacity
    No Sun
    and
    Wind

    ACAR-1 355.0 179.9 19 12 7 136.7 3.472 0.684 17.36 332.9 495.4 8.54 3872 0.0514 0.169 356 Amps 519 Amps 560 Amps
    ACAR-10 853.7 432.6 37 30 7 151.9 3.858 1.06 27.01 801.3 1192.3 17.46 7918 0.0208 0.068 657 Amps 908 Amps 995 Amps
    ACAR-11 853.7 432.6 37 18 19 151.9 3.858 1.06 27.01 799.8 1190.2 21.51 9756 0.0218 0.072 644 Amps 890 Amps 976 Amps
    ACAR-12 927.2 469.8 37 30 7 158.3 4.021 1.11 28.15 870.2 1294.9 18.96 8599 0.0192 0.063 695 Amps 955 Amps 1049 Amps
    ACAR-13 927.2 469.8 37 18 19 158.3 4.021 1.11 28.15 868.7 1292.6 23.36 10596 0.0201 0.066 681 Amps 937 Amps 1028 Amps
    ACAR-14 1024.5 519.1 37 30 7 166.4 4.227 1.16 29.59 961.6 1430.8 20.95 9502 0.0173 0.057 743 Amps 1016 Amps 1117 Amps
    ACAR-15 1024.5 519.1 37 18 19 166.4 4.227 1.16 29.59 959.8 1428.2 26.35 11954 0.0182 0.060 729 Amps 996 Amps 1096 Amps
    ACAR-16 1081.0 547.7 37 30 7 170.9 4.341 1.20 30.39 1014.3 1509.2 21.89 9927 0.0164 0.054 770 Amps 1049 Amps 1155 Amps
    ACAR-17 1081.0 547.7 37 18 19 170.9 4.341 1.20 30.36 1012.4 1506.5 27.23 12350 0.0173 0.057 755 Amps 1029 Amps 1133 Amps
    ACAR-18 1109.0 561.9 37 30 7 173.1 4.397 1.21 30.78 1040.5 1548.3 22.67 10583 0.016 0.053 783 Amps 1066 Amps 1174 Amps
    ACAR-19 1109.0 561.9 37 18 19 173.1 4.397 1.21 30.78 1038.7 1545.5 27.93 12670 0.0168 0.055 768 Amps 1045 Amps 1151 Amps
    ACAR-2 400.0 202.7 19 12 7 145.1 3.686 0.726 18.43 375.1 558.1 9.52 4320 0.0456 0.150 387 Amps 560 Amps 605 Amps
    ACAR-20 1172.0 593.9 37 30 7 178.0 4.521 1.25 31.65 1100.3 1637.2 23.97 10873 0.0152 0.050 813 Amps 1102 Amps 1215 Amps
    ACAR-21 1172.0 593.9 37 18 19 178.0 4.521 1.25 31.65 1098.3 1634.3 29.54 13397 0.0159 0.052 797 Amps 1081 Amps 1192 Amps
    ACAR-22 1198.0 607.0 37 30 7 179.9 4.569 1.26 31.99 1123.9 1672.4 24.48 11106 0.0148 0.049 824 Amps 1116 Amps 1231 Amps
    ACAR-23 1198.0 607.0 37 18 19 179.9 4.569 1.26 31.99 1121.9 1669.4 30.17 13685 0.0156 0.051 808 Amps 1095 Amps 1208 Amps
    ACAR-24 1200.0 608.0 37 30 7 180.1 4.575 1.26 32.02 1126.4 1676.1 24.54 11131 0.0148 0.049 826 Amps 1118 Amps 1234 Amps
    ACAR-25 1200.0 608.0 37 24 13 180.1 4.575 1.26 32.02 1125.4 1674.6 27.11 12295 0.0152 0.050 818 Amps 1107 Amps 1222 Amps
    ACAR-26 1200.0 608.0 37 18 19 180.1 4.575 1.26 32.02 1124.4 1673.1 30.24 13715 0.0155 0.051 810 Amps 1097 Amps 1210 Amps
    ACAR-27 1200.0 608.0 61 48 13 140.3 3.564 1.26 32.07 1126.8 1676.7 24.71 11210 0.0148 0.049 825 Amps 1117 Amps 1233 Amps
    ACAR-28 1280.0 648.6 37 30 7 186.0 4.724 1.30 33.07 1201.4 1787.7 26.17 11872 0.0139 0.046 861 Amps 1162 Amps 1284 Amps
    ACAR-29 1280.0 648.6 37 18 19 186.0 4.724 1.30 33.07 1199.3 1784.5 32.25 14629 0.0146 0.048 845 Amps 1140 Amps 1260 Amps
    ACAR-3 465.9 236.1 19 12 7 156.6 3.978 0.783 19.89 436.9 650.1 10.98 4981 0.0391 0.128 429 Amps 616 Amps 667 Amps
    ACAR-30 1361.0 689.6 61 42 19 149.4 3.795 1.34 34.15 1277.0 1900.2 30.31 13750 0.0133 0.044 891 Amps 1198 Amps 1325 Amps
    ACAR-31 1527.0 773.7 61 42 19 158.2 4.018 1.42 36.16 1431.9 2130.7 33.60 15243 0.0118 0.039 960 Amps 1281 Amps 1421 Amps
    ACAR-32 1703.0 862.9 61 42 19 167.1 4.244 1.50 38.20 1597.5 2377.2 37.49 17007 0.0106 0.035 1030 Amps 1366 Amps 1519 Amps
    ACAR-33 1933.0 979.5 61 42 19 178.0 4.521 1.60 40.69 1812.8 2697.4 42.54 19298 0.00936 0.031 1115 Amps 1468 Amps 1637 Amps
    ACAR-34 2267.0 1148.7 61 42 19 192.8 4.897 1.74 44.07 2126.7 3164.6 49.91 22640 0.00805 0.026 1231 Amps 1604 Amps 1796 Amps
    ACAR-35 2339.0 1185.2 61 42 19 195.8 4.973 1.76 44.76 2193.4 3263.8 51.48 23350 0.00781 0.026 1254 Amps 1632 Amps 1828 Amps
    ACAR-36 2493.0 1263.2 91 72 19 165.5 4.204 1.82 46.24 2339.1 3480.6 50.44 22879 0.00722 0.024 1309 Amps 1697 Amps 1904 Amps
    ACAR-37 2493.0 1263.2 91 54 37 165.5 4.204 1.82 46.24 2336.6 3476.8 57.58 26119 0.00743 0.024 1297 Amps 1681 Amps 1886 Amps
    ACAR-4 500.0 253.4 19 12 7 162.2 4.120 0.811 20.60 468.7 397.4 11.78 5344 0.0365 0.120 451 Amps 644 Amps 698 Amps
    ACAR-5 500.0 253.4 37 18 19 116.2 2.951 0.813 20.66 468.1 696.5 13.22 5996 0.0373 0.122 447 Amps 638 Amps 692 Amps
    ACAR-6 503.6 255.2 19 12 7 162.8 4.135 0.814 20.68 472.2 702.6 11.87 5383 0.0362 0.119 453 Amps 646 Amps 701 Amps
    ACAR-7 653.1 330.9 19 12 7 185.4 4.709 0.927 23.55 612.4 911.2 15.39 6982 0.0279 0.092 541 Amps 760 Amps 829 Amps
    ACAR-8 739.8 374.9 37 30 7 141.4 3.592 0.990 25.14 694.3 1033.2 15.35 6961 0.024 0.079 596 Amps 831 Amps 908 Amps
    ACAR-9 739.8 374.9 37 18 19 141.4 3.592 0.990 25.14 693.1 1031.3 18.77 8516 0.0252 0.083 585 Amps 815 Amps 891 Amps